NS10000 disinfection device



Specifications

Suspended programmable orientable nebulizer with device for oscillating around its diffusion axis. Flow rate 10,000 mL / h

Technical sheet

Fan : 385 m3/h - 24 V CC - IP68
Engine : 
BRUSHLESS
Pump : 
24VDC peristaltic
Hose Pump : 
Pharmed 5X7mm
Disc rotation speed (rpm) : Greater than 40,000 RPM
Power Supply Input : 100 to 240 V, 50-60 Hz, 2A
Power Supply Output : 24Vcc / 5A
Max power consumption : 100Watts
Liquid flow (ml / h) : 10,000
Liquid presence control : Optical sensor
Tank : Without
Drums : Without
Charging time (h) : X
Battery life (min.) : X
Drop size (µm) :  <15µm
Width (mm) : 180
Height (mm) : 750
Length (mm) : 160
Weight (kg) : 5
Automatic drain : Yes
Material : INOX 304L
Seals : PTFE
Sound level : 64dBA

Find out more

 

This nebulizer can be swiveled and rotated alternately to disperse aerosols over 360 °. It works on mains and is equipped with a very powerful fan which drives the droplets over distances of several meters. This nebulizer is particularly intended to treat very large volumes and to operate in an open or semi-open environment.

 

  • The disk is supplied with liquid via a peristaltic pump which sucks the liquid from a container via a flexible PTFE hose.
  • The rotational movement of the nebulizer is provided by a stepper motor.
  • The nebulizer is programmed through push buttons placed on the front side next to the display screen. It can operate continuously, spraying the entire quantity of liquid programmed in one go or cyclically alternating between spraying periods and resting periods.
  • Programming is done simply by entering the various functions. The effective spraying time is obtained by dividing the amount of liquid to be nebulized. For example with a flow rate of 400 mL / h, it takes a total time of 30 minutes to spray continuously 200 Ml
  • Function C (cycles) fixes the number of spraying cycles It is adjustable from 1 to 99. The value 1 corresponds to continuous operation.
  • Function D (duration) corresponds to the time of each effective spraying cycle. It is adjustable from 0 to 99 minutes and 59 seconds in steps of 1 second. For example, if you choose 10 spray cycles to nebulize 200 Ml., The duration D to program is 3 minutes.
  • The R (delay) function defines the time both the time after which the device begins to nebulize and the time between the end of one spray cycle and the start of the next. It is adjustable from 0 to 9 hours and 59 minutes in steps of 1 minute. For example, if you choose a pause time of 5 minutes between the end of one spraying and the start of the next, the nebulization will start after 5 minutes and will continue for 80 minutes.

 

Other functions and controls

  • The nebulizer is provided with an LED allowing to visualize from a distance its good functioning.
  • The nebulizer is equipped with a liquid presence sensor (CPL) placed just upstream of the disc which automatically stops the rotation of the disc when no liquid is detected.
  • At the end of spraying, the nebulizer automatically empties the hydraulic circuit and discharges the non-sprayed liquid into the canister.
  • Liquid compatibility: This nebulizer accepts all viscous or non-viscous liquids, non-flammable (the device is not ATEX certified) and compatible with the following materials: 304L stainless steel, silicone, PTFE loaded with graphite and carbon (gasket ), novoprene, edible fat. For some liquids, cleaning of the hydraulic circuit may be necessary to avoid deposits. You just have to program a spraying sequence with a cleaning liquid.
  • Several nebulizers can be associated with a centralized control. Contact us for more information.

You will also like