NT2000 disinfection device



Specifications

Programmable table top nebulizer with vertical nebulization. Flow rate 2000 mL / h

 

IN STOCK

Technical sheet

Fan : 385 m3/h - 24 V CC - IP68
Engine : 
BRUSHLESS
Pump : 
24VDC peristaltic
Hose Pump : 
Pharmed 2X4mm
Disc rotation speed (rpm) : Greater than 40,000 RPM
Power Supply Input : 100 à 240 V, 50-60 Hz,2A
Power Supply Output : 18Vcc / 5A
Max power consumption : 65Watts
Liquid flow (ml / h) : 2000
Liquid presence control : Optical sensor
Tank : 2 Cans of 1L
Drums : Without
Charging time (h) : X
Battery life (min.) : X
Drop size (µm) : <15µm
Width (mm) : 160
Height (mm) : 240
Length (mm) : 355
Weight (kg) : 5.5
Automatic drain : Yes
Material : INOX 304L
Seals : PTFE
Sound level : 64dBA

Find out more

 

This compact, mains-operated nebulizer disperses the aerosol vertically upwards with the wind of a fan which carries the droplets emitted near the edge of the disc.

 

  • The disk is supplied with liquid via a peristaltic pump which draws the liquid contained in a 1 liter container integrated into the device via a flexible silicone hose.
  • The nebulizer is programmed through push buttons placed on the front side next to the display screen. It can operate continuously, spraying all the programmed amount of liquid at once or cyclically alternating periods of spraying and periods of rest.
  • Programming is done simply by entering the various functions. The effective duration of spraying is obtained by dividing the quantity of liquid to be nebulized by the flow rate. For example with a flow rate of 400 mL / h, it takes a total of 30 minutes to continuously spray 200 Ml
  • Function C (cycles) fixes the number of spraying cycles It is adjustable from 1 to 99. The value 1 corresponds to continuous operation.
  • Function D (duration) corresponds to the time of each effective spraying cycle. It is adjustable from 0 to 99 minutes and 59 seconds in steps of 1 second. For example, if you choose 10 spray cycles to nebulize 200 Ml., The duration D to program is 3 minutes.
  • The R (delay) function defines the time both the time after which the device begins to nebulize and the time between the end of one spray cycle and the start of the next. It is adjustable from 0 to 9 hours and 59 minutes in steps of 1 minute. For example, if you choose a pause time of 5 minutes between the end of one spraying and the start of the next, the nebulization will start after 5 minutes and will continue for 80 minutes.
  • Other functions and controls
  • The nebulizer is equipped with an LED allowing remote visualization of its correct functioning.
  • The nebulizer is fitted with a liquid presence sensor (CPL) placed just upstream of the disc which automatically stops the rotation of the disc when no liquid is detected.
  • At the end of spraying, the nebulizer automatically empties the hydraulic circuit and delivers the non-sprayed liquid back into the container.
  • Liquid compatibility: This nebulizer accepts all viscous or non-viscous liquids, non-flammable (the device is not ATEX certified) and compatible with the following materials: 304L stainless steel, silicone, PTFE loaded with graphite and carbon (gasket ), novoprene, edible fat. For some fluids, cleaning the hydraulic circuit may be necessary to prevent deposits. It is then sufficient to program a spraying sequence with a cleaning liquid.

 